{"id":1323,"date":"2026-01-20T09:57:51","date_gmt":"2026-01-20T09:57:51","guid":{"rendered":"https:\/\/www.facadeaccesssolutions.com\/apac\/?page_id=1323"},"modified":"2026-01-20T10:06:17","modified_gmt":"2026-01-20T10:06:17","slug":"codes-regulations-standards","status":"publish","type":"page","link":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/","title":{"rendered":"Codes, Regulations, &amp; Standards"},"content":{"rendered":"\r\n<section class=\"breadcrumbs\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"100\">\r\n    <div class=\"content_holder content_holder_1570\">\r\n    \t<ul><li class=\"main-home\"><span property=\"itemListElement\" typeof=\"ListItem\"><a property=\"item\" typeof=\"WebPage\" title=\"Go to FACADE ACCESS SOLUTIONS Sites.\" href=\"https:\/\/www.facadeaccesssolutions.com\" class=\"main-home\" ><span property=\"name\">FACADE ACCESS SOLUTIONS Sites<\/span><\/a><meta property=\"position\" content=\"1\"><\/span><\/li>\n<li class=\"home\"><span property=\"itemListElement\" typeof=\"ListItem\"><a property=\"item\" typeof=\"WebPage\" title=\"Go to Facade Access Solutions APAC.\" href=\"https:\/\/www.facadeaccesssolutions.com\/apac\" class=\"home\" aria-current=\"page\"><span property=\"name\">Home<\/span><\/a><meta property=\"position\" content=\"2\"><\/span><\/li>\n<\/ul>\r\n    <\/div>\r\n<\/section>\n\n<section class=\"page_title \" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"200\">\n    <div class=\"content_holder content_holder_1570\">\n        <h1>Codes, Regulations, &amp; Standards<\/h1>\n    <\/div>\n<\/section>\n\n\n\r\n<section class=\"solutions_intro solutions_intro_1 solutions_intro_flip solutions_intro_vc \">\r\n    <div class=\"content_holder content_holder_1570 clearfix\">\r\n\r\n\t\t                <div class=\"sol_right\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"300\">\r\n        \t<a href=\"https:\/\/www.facadeaccesssolutions.com\/apac\/contact\/\" target=\"\" class=\"img_zoom\">            <img decoding=\"async\" src=\"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-content\/uploads\/sites\/15\/2026\/01\/building-maintenance-unit-881x515_c.jpg\" alt=\"building maintenance unit\">\r\n            <\/a>        <\/div>\r\n            \r\n        <div class=\"sol_left\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"400\">\r\n        \t<h4>Looking for a compliant and reliable facade access equipment like davits or building maintenance unit (BMU)?<\/h4>            <div class=\"site_contents\">\r\n            <p>Global markets follow different statutory rules for Suspended Access and Fall Protection. Understanding local codes, labor laws and technical requirements often consumes valuable time and resources. Our team provides expert guidance in navigating international and regional regulations helping you create a safety solution that meets global access requirements, supports workplace safety and delivers efficient performance for projects anywhere in the world.<\/p>\n            <\/div>\r\n            \t            <a href=\"https:\/\/www.facadeaccesssolutions.com\/apac\/contact\/\" class=\"site_btn site_btn_sm\" target=\"\">\r\n\t\t\t\t\tContact Us                <\/a>\r\n                &nbsp;&nbsp;&nbsp;\r\n                        \r\n                    <\/div>\r\n    <\/div>\r\n<\/section>\r\n\r\n\r\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.34%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:900%\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" id=\"h-our-compliance-list-is-comprehensive-and-we-further-review-all-applicable-local-codes-and-project-specific-requirements-to-ensure-complete-adherence-beyond-federal-state-and-provincial-standards\">Our compliance list is comprehensive, and we further review all applicable local codes and project-specific requirements to ensure complete adherence beyond Federal, State, and Provincial standards.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><\/div>\n<\/div>\n\n\n\r\n<section class=\"accordion_list\" style=\"padding-top:50px; padding-bottom:50px;\">\r\n    <div class=\"content_holder content_holder_1570 clearfix\">\r\n\t\t<div class=\"acc_wrap\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"100\">\r\n        \t<h2>Australia<\/h2>                                    \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Legislation &amp; Codes of Practice <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>Work Health and Safety Act 2011 (WHS Act):<\/strong> Primary workplace safety legislation.<\/li>\n<li><strong>Work Health and Safety Regulation: <\/strong>2011\/2025 Fall prevention, plant, inspection &amp; competence requirements.<\/li>\n<li><strong>Code of Practice:<\/strong> Managing the Risk of Falls at Workplaces Guidance on hierarchy of fall controls.<\/li>\n<li><strong>Code of Practice:<\/strong> Managing Risks of Plant Includes BMUs and lifting equipment.<\/li>\n<li><strong>Rope Access Guidance (ISO 22846-aligned):<\/strong> Nationally accepted safe practice for rope access.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Height Safety &amp; Fall-Arrest Standards (AS\/NZS 1891) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS\/NZS 1891.1:&nbsp;<\/strong>2020 Harnesses &amp; associated equipment.<\/li>\n<li><strong>AS\/NZS 1891.2:&nbsp;<\/strong>2001 Horizontal lifeline &amp; rail systems.<\/li>\n<li><strong>AS\/NZS 1891.3:<\/strong> 2020 Fall-arrest devices.<\/li>\n<li><strong>AS\/NZS 1891.4:<\/strong> 2025 Selection, use &amp; maintenance requirements.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Anchor Systems <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS\/NZS 5532:&nbsp;<\/strong>2013 Manufacturing\/testing of single-point anchors.<\/li>\n<li>AS\/NZS 1891.2 Horizontal lifeline &amp; rail anchor systems.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Rope Access Standards (ISO 22846) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS\/NZS ISO 22846.1:<\/strong> 2020 Fundamental principles for rope-access systems.<\/li>\n<li><strong>AS\/NZS ISO 22846.2:<\/strong> 2020 Operational code of practice.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">BMU \/ Fa\u00e7ade Access Systems <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS 1418.1:<\/strong> General requirements for cranes\/hoists.<\/li>\n<li><strong>AS 1418.15:<\/strong> Building Maintenance Units &ndash; primary design standard.<\/li>\n<li><strong>AS 2550.1:<\/strong> Safe use of cranes.<\/li>\n<li><strong>AS 2550.15:<\/strong> Safe use of BMUs &ndash; inspection &amp; operation.<\/li>\n<li><strong>AS\/NZS 1170:<\/strong> Series Structural design actions for loads.<\/li>\n<li><strong>AS\/NZS 3000 (Wiring Rules):<\/strong> Electrical installation safety requirements for BMUs.<\/li>\n<li><strong>AS 61439:<\/strong> Series Low-voltage switchgear and controlgear assemblies used in BMU control panels.<\/li>\n<li><strong>AS\/NZS 60204.1:<\/strong> Safety of machinery &ndash; Electrical equipment of machines, relevant to BMU electrical systems.<\/li>\n<li><strong>AS\/NZS 3012:<\/strong> Electrical installations for construction &amp; demolition sites &ndash; applicable during BMU installation\/commissioning.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Permanent Access Systems <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS 1657:<\/strong> 2018 Walkways, platforms &amp; fixed ladders.<\/li>\n<li><strong>AS\/NZS 1892:<\/strong> Series Portable ladder requirements.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Scaffolding Standards <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS\/NZS 1576 Series:<\/strong> Scaffolding components &amp; suspended systems.<\/li>\n<li><strong>AS\/NZS 4576:<\/strong> Scaffolding guidelines.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Additional Relevant Standards <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>AS\/NZS 4488:<\/strong> Series Legacy rope-access standards.<\/li>\n<li><strong>AS\/NZS 4142.3:<\/strong> Static kernmantle rope specifications.<\/li>\n<li><strong>AS\/NZS 2865:<\/strong> Confined spaces requirements.<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                    <\/div>\r\n    <\/div>\r\n<\/section>\r\n\r\n\n\n\r\n<section class=\"accordion_list\" style=\"padding-top:px; padding-bottom:50px;\">\r\n    <div class=\"content_holder content_holder_1570 clearfix\">\r\n\t\t<div class=\"acc_wrap\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"100\">\r\n        \t<h2>China<\/h2>                                    \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">National Standards &amp; Codes (Facade Access \/ BMUs) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>GB\/T 19154-2017:<\/strong> Building Maintenance Unit (BMU). Core national standard covering scope, definitions, types, technical requirements, structural\/stability and mechanical design, electrical\/control systems, test methods, inspection rules, marking, and documentation.<\/li>\n<li><strong>GB 50057 (Bibliography in GB\/T 19154):<\/strong> Code for design protection of structures against lightning (relevant where BMU rails\/structures interface with the building\u2019s lightning protection design).<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Type-Tests, Rail\/Monorail &amp; Control Systems (Annexes in GB\/T 19154) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>Annex A\u2013C:<\/strong> Type-tests for platforms, hoists\/secondary devices, and suspension rigs (conformity &amp; safety validation).<\/li>\n<li><strong>Annex D:<\/strong> Guidance for presenting\/interpreting loads imposed on equipment and building structures (coordination with structural engineers).<\/li>\n<li><strong>Annex E:<\/strong> Restraint system analysis (ISA pins, soft ropes, etc.)\u2014design guidance.<\/li>\n<li><strong>Annex F:<\/strong> Requirements for wireless control systems (when BMUs\/cradles use wireless control).<\/li>\n<li><strong>Annex G:<\/strong> Design requirements for rail tracks, monorails, and support systems (including loads transferred to the building).<\/li>\n<li><strong>Annex H:<\/strong> Travelling ladders and\/or gantries (where applicable to fa\u00e7ade access).<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Inspection, Operation &amp; Documentation (GB\/T 19154 chapters) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>Chapters 12\u201313:<\/strong> Test methods and inspection rules for BMUs and components.<\/li>\n<li><strong>Chapter 14:<\/strong> Marking (machine labels\/identification).<\/li>\n<li><strong>Chapter 15:<\/strong> Accompanying documents (manuals, certificates, records).<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Notes on Application <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li>The standard explicitly addresses significant BMU hazards and prescribes technical measures to eliminate or reduce risk, and it assumes site-specific agreements between supplier and user about local installation conditions.<\/li>\n<li>It also states building parapets\/roofs must have adequate strength for BMU installation (coordination with structural design)<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                    <\/div>\r\n    <\/div>\r\n<\/section>\r\n\r\n\n\n\r\n<section class=\"accordion_list\" style=\"padding-top:px; padding-bottom:50px;\">\r\n    <div class=\"content_holder content_holder_1570 clearfix\">\r\n\t\t<div class=\"acc_wrap\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"100\">\r\n        \t<h2>Hong Kong<\/h2>                                    \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Primary Legislation <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<h3>Factories and Industrial Undertakings Ordinance (FIUO), Cap. 59<\/h3>\n<p>Governs workplace safety, including work-at-height and use of suspended working platforms.<\/p>\n<h3>Factories and Industrial Undertakings (Suspended Working Platforms) Regulation (SWPR), Cap. 59AC<\/h3>\n<p>The main statutory regulation controlling design, installation, safe operation, inspection, testing, and maintenance of Suspended Working Platforms (SWPs).<\/p>\n<h3>Factories and Industrial Undertakings (Lifting Appliances and Lifting Gear) Regulations (LALGR)<\/h3>\n<p>Applies to lifting appliances, lifting gear, and certain suspended access equipment categories.<\/p>\n<h3>Construction Sites (Safety) Regulations (CSSR)<\/h3>\n<p>Relevant for construction-stage fa&ccedil;ade access activities, including certain lifting and suspended gear.<\/p>\n<h3>Buildings Ordinance, Cap. 123<\/h3>\n<p>Requires approval for anchorage, structural loads, and installation details affecting the building structure.<\/p>\n<h3>Engineers Registration Ordinance, Cap. 409<\/h3>\n<p>Regulates the qualifications of engineers involved in design, testing, certification, and approval.<\/p>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Mandatory Codes of Practice (HK Labour Department) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<p>The official COP under FIUO, providing mandatory safety and operational requirements, including:<\/p>\n<ul>\n<li>Design loads &amp; wind loading requirements<\/li>\n<li>Anchorage &amp; structural support requirements<\/li>\n<li>Safe operation, weather restrictions, training, marking &amp; use rules<\/li>\n<li>Maintenance &amp; examination requirements<\/li>\n<li>Certification, display and record-keeping<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Referenced Local Codes <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<h3>Code of Practice on Wind Effects Hong Kong 1983<\/h3>\n<p>Required for design of SWP stability and wind loading in docked\/operating conditions.<\/p>\n<h3>Code of Practice for the Structural Use of Steel, 1987<\/h3>\n<p>Referenced when designing fixings, anchorage, and structural connections for BMUs\/SWPs.<\/p>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">International Standards    <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<p>The Hong Kong COP recognises equivalent international standards if they meet or exceed referenced requirements. Included standards:<\/p>\n<h3>British Standards<\/h3>\n<ul>\n<li><strong>BS 6037:1990<\/strong> &ndash; Permanently Installed Suspended Access Equipment<\/li>\n<li><strong>BS 2830:1994<\/strong> &ndash; Suspended Access Equipment<\/li>\n<li><strong>BS 5974:1990<\/strong> &ndash; Temporarily Installed Suspended Scaffolds<\/li>\n<li><strong>BS EN 361:1993<\/strong> &ndash; Fall Protection: Full Body Harnesses<\/li>\n<li><strong>BS EN 795:1997<\/strong> &ndash; Anchor Devices for Fall Protection<\/li>\n<\/ul>\n<h3>European Standards<\/h3>\n<ul>\n<li><strong>prEN 1808:1995<\/strong> &ndash; Suspended Access Equipment Safety Requirements<\/li>\n<\/ul>\n<h3>American Standards (ANSI)<\/h3>\n<ul>\n<li><strong>ANSI A120.1<\/strong> &ndash; Safety Requirements for Powered Platforms for Exterior Building Maintenance<\/li>\n<li><strong>ANSI A10.8<\/strong> &ndash; Scaffolding Safety Requirements<\/li>\n<\/ul>\n<h3>Singapore Standards<\/h3>\n<ul>\n<li><strong>CP 20:1981<\/strong> &ndash; Code of Practice for Suspended Scaffolding<\/li>\n<\/ul>\n<h3>Japan Ministry of Labour Technical Guidelines<\/h3>\n<p>Referenced for safety standards relating to suspended gondolas.<\/p>\n<h3>Guidance from Labour Department (HK)<\/h3>\n<p>Guidance note on safety belts and anchorage systems<\/p>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                    <\/div>\r\n    <\/div>\r\n<\/section>\r\n\r\n\n\n\r\n<section class=\"accordion_list\" style=\"padding-top:px; padding-bottom:50px;\">\r\n    <div class=\"content_holder content_holder_1570 clearfix\">\r\n\t\t<div class=\"acc_wrap\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"100\">\r\n        \t<h2>Malaysia<\/h2>                                    \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Codes and Regulations <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<p>In Malaysia, the Department of Safety and Health (DOSH) under the Ministry of Human Resources uses these guidelines as a reference for Working at Height. For BMU design, they follow the standard from the country of origin where the machine is manufactured.<\/p>\n<p>For example:<\/p>\n<ul>\n<li>If the machine is imported from Europe, they refer to the EN1808 code.<\/li>\n<li>If it comes from China, they refer to the Chinese standard.<\/li>\n<\/ul>\n<p>As of now, Malaysia does not have a specific standard for BMU machine design.<\/p>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                    <\/div>\r\n    <\/div>\r\n<\/section>\r\n\r\n\n\n\r\n<section class=\"accordion_list\" style=\"padding-top:px; padding-bottom:50px;\">\r\n    <div class=\"content_holder content_holder_1570 clearfix\">\r\n\t\t<div class=\"acc_wrap\" data-aos=\"fade-up\" data-aos-duration=\"600\" data-aos-easing=\"ease-out\" data-aos-delay=\"100\">\r\n        \t<h2>Singapore<\/h2>                                    \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Suspended Access Equipment &amp; Hoist System (Singapore Standards) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>SS 598<\/strong> &ndash; Code of Practice for Safe Use of Suspended Scaffolds<\/li>\n<li><strong>SS 570<\/strong> &ndash; Personal Protective Equipment (PPE) for Protection Against Falls from Height<\/li>\n<li><strong>SS 497<\/strong> &ndash; Code of Practise for Gantry Crane &#8211; Overhead Crane &#8211; Monorail Hoist<\/li>\n<li><strong>WSH Guidelines on Suspended Scaffolds<\/strong> &ndash; WSH Council<\/li>\n<li><strong>Building Control Regulations (BCA)<\/strong> &ndash; Requirements for fa&ccedil;ade access and BMU installation<\/li>\n<\/ul>\n<h3>International Standards<\/h3>\n<ul>\n<li>EN 1808 &ndash; Safety requirements on suspended access equipment<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">Safety Lifeline System \/ Fall Protection (Singapore Standards) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li><strong>SS 528<\/strong> &ndash; Code of Practice for Personal Fall Arrest Systems<\/li>\n<li><strong>SS 570<\/strong> &ndash; Personal protective equipment for working at height<\/li>\n<li><strong>WSH (Work At Heights) Regulations &ndash; Mandatory requirements for fall protection<\/strong><\/li>\n<\/ul>\n<h3>International Standards<\/h3>\n<ul>\n<li><strong>EN 795<\/strong> &ndash; Anchor devices for fall protection<\/li>\n<li><strong>EN 363<\/strong> &ndash; Full body harnesses and fall arrest systems<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                        \t                    <div class=\"acc_item\">\r\n                        <div class=\"acc_title\">General Workplace Safety on Site (Singapore Legislation &amp; Guidelines) <span><\/span><\/div>\r\n                        <div class=\"acc_txt\">\r\n                            <div class=\"site_contents\">\r\n                            \t<ul>\n<li>Workplace Safety and Health Act (WSH Act)<\/li>\n<li>WSH (Risk Management) Regulations<\/li>\n<li>WSH (General Provisions) Regulations<\/li>\n<li>Code of Practice on Workplace Safety and Health (CP79)<\/li>\n<li>WSH Guidelines: Working at Height, Lifting Operations, Electrical Safety, etc.<\/li>\n<\/ul>\n<h3>International Standard<\/h3>\n<ul>\n<li><strong>ISO 45001<\/strong> &ndash; Occupational health and safety management systems<\/li>\n<\/ul>\n                            <\/div>\r\n                        <\/div>\r\n                    <\/div>\r\n                                    <\/div>\r\n    <\/div>\r\n<\/section>\r\n\r\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Our compliance list is comprehensive, and we further review all applicable local codes and project-specific &#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_trash_the_other_posts":false,"editor_notices":[],"footnotes":""},"class_list":["post-1323","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.1 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Codes, Regulations, &amp; Standards | Facade Access Solutions APAC<\/title>\n<meta name=\"description\" content=\"Facade access codes, rules, and regulations covering safety standards, compliance requirements, and best practices for building maintenance systems worldwide.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Codes, Regulations, &amp; Standards\" \/>\n<meta property=\"og:description\" content=\"Facade access codes, rules, and regulations covering safety standards, compliance requirements, and best practices for building maintenance systems worldwide.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/\" \/>\n<meta property=\"og:site_name\" content=\"Facade Access Solutions APAC\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-20T10:06:17+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/codes-regulations-standards\\\/\",\"url\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/codes-regulations-standards\\\/\",\"name\":\"Codes, Regulations, &amp; Standards | Facade Access Solutions APAC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/#website\"},\"datePublished\":\"2026-01-20T09:57:51+00:00\",\"dateModified\":\"2026-01-20T10:06:17+00:00\",\"description\":\"Facade access codes, rules, and regulations covering safety standards, compliance requirements, and best practices for building maintenance systems worldwide.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/codes-regulations-standards\\\/#breadcrumb\"},\"inLanguage\":\"en-AU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/codes-regulations-standards\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/codes-regulations-standards\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Codes, Regulations, &amp; Standards\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/#website\",\"url\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/\",\"name\":\"Facade Access Solutions APAC\",\"description\":\"Part Of Alimak Group\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.facadeaccesssolutions.com\\\/apac\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-AU\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Codes, Regulations, &amp; Standards | Facade Access Solutions APAC","description":"Facade access codes, rules, and regulations covering safety standards, compliance requirements, and best practices for building maintenance systems worldwide.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/","og_locale":"en_US","og_type":"article","og_title":"Codes, Regulations, &amp; Standards","og_description":"Facade access codes, rules, and regulations covering safety standards, compliance requirements, and best practices for building maintenance systems worldwide.","og_url":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/","og_site_name":"Facade Access Solutions APAC","article_modified_time":"2026-01-20T10:06:17+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/","url":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/","name":"Codes, Regulations, &amp; Standards | Facade Access Solutions APAC","isPartOf":{"@id":"https:\/\/www.facadeaccesssolutions.com\/apac\/#website"},"datePublished":"2026-01-20T09:57:51+00:00","dateModified":"2026-01-20T10:06:17+00:00","description":"Facade access codes, rules, and regulations covering safety standards, compliance requirements, and best practices for building maintenance systems worldwide.","breadcrumb":{"@id":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/#breadcrumb"},"inLanguage":"en-AU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.facadeaccesssolutions.com\/apac\/codes-regulations-standards\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.facadeaccesssolutions.com\/apac\/"},{"@type":"ListItem","position":2,"name":"Codes, Regulations, &amp; Standards"}]},{"@type":"WebSite","@id":"https:\/\/www.facadeaccesssolutions.com\/apac\/#website","url":"https:\/\/www.facadeaccesssolutions.com\/apac\/","name":"Facade Access Solutions APAC","description":"Part Of Alimak Group","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.facadeaccesssolutions.com\/apac\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-AU"}]}},"_links":{"self":[{"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/pages\/1323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/comments?post=1323"}],"version-history":[{"count":2,"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/pages\/1323\/revisions"}],"predecessor-version":[{"id":1329,"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/pages\/1323\/revisions\/1329"}],"wp:attachment":[{"href":"https:\/\/www.facadeaccesssolutions.com\/apac\/wp-json\/wp\/v2\/media?parent=1323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}